Introduction
The S & Drive connection is a long-established method for joining rectangular metal duct sections. Its simple cleat-based construction and minimal hardware requirements have made it a cost-effective alternative to traditional angle-iron flange connections in suitable applications.
Compared with flange systems such as TDF/TDC, S & Drive connections feature a simpler joint structure and generally require less complex forming equipment. They remain commonly used for smaller rectangular ducts and lower-pressure applications.
This guide covers:
- What an S & Drive duct connection is
- How S Cleats and Drive Cleats are made
- How to install an S & Drive connection
- Key advantages and limitations
- S & Drive vs. TDF/TDC flange connections
- How to choose the right forming machine
What Is an S & Drive Duct Connection?
An S & Drive Duct Connection, also known as an S & Drive Cleat Connection, is a flangeless mechanical connection used to join rectangular metal ducts, typically galvanized steel ducts. Instead of using traditional angle steel flanges or integrally formed flanges, it connects two duct sections using two separately formed metal components: the S Cleat and the Drive Cleat, the latter also commonly referred to as a C Cleat.
During assembly, the two types of cleats are installed on two pairs of opposite sides of the rectangular duct joint and perform different functions:
- S Cleat:Typically roll-formed from thin sheet metal, the S Cleat has an approximately S-shaped cross-section with two opposing channels. The corresponding edges of two adjacent duct sections fit into these channels, keeping the sections aligned and connected in the same plane. The S Cleat primarily provides connection and alignment.
- Drive Cleat / C Cleat:Also typically roll-formed from thin sheet metal, the Drive Cleat has an open-channel or approximately C-shaped cross-section. It is slid or driven along the aligned duct edges to lock the two duct sections together. After installation, its ends may also be folded or secured according to the specific joint configuration. The Drive Cleat primarily provides locking and fastening.
In a typical S & Drive Connection, S Cleats are usually installed on the two longer opposite sides of the rectangular duct, while Drive Cleats are installed on the other two shorter sides. Together, they form a complete mechanical connection around all four sides of the duct.
Simply put, the S Cleat provides connection and alignment, while the Drive Cleat provides locking and fastening.
How Are S & Drive Cleats Made?
S Cleats and Drive Cleats are typically manufactured from galvanized steel sheet or other thin sheet metal through continuous roll forming. Depending on the required cleat or lock profile, an appropriate Lock Forming Machine can be used for production.
A Lock Forming Machine is a common roll-forming machine used in duct fabrication. Depending on its roller configuration and forming stations, it can produce not only S Cleats and Drive Cleats but also different duct seams and edge profiles such as Pittsburgh Lock and Snap Lock. The specific profiles available depend on the machine model and roller configuration.
The machine typically consists of a feeding section, multiple forming rollers, a drive system, and a machine frame.
During operation, sheet metal or metal strip is continuously fed into the roller sets and progressively bent through multiple forming stations until the required cross-sectional profile is produced.
A typical forming process can be summarized as:
Metal Sheet/Strip → Feeding → Progressive Roll Forming → Required Profile
For an S & Drive Connection, the machine must have the appropriate roller configuration to form the required S Cleat or Drive Cleat profile. After forming, the profile is cut to the required length according to the actual duct dimensions.
Continuous roll forming helps improve both profile consistency and production efficiency. In actual production, particular attention should be paid to roller forming accuracy, feeding stability, finished profile consistency, and straightness, as these factors directly affect the assembly quality of the subsequent duct connection.
How to Install an S & Drive Duct Connection
Proper installation of an S & Drive Connection is important for maintaining the stability and airtightness of the duct joint. Improper installation can result in loose joints, duct deformation, or air leakage. The following describes a typical S & Drive installation procedure; specific requirements should be determined according to the duct specifications, system pressure, and applicable project construction standards.
Step 1: Preparation
- Inspect the duct ends: Make sure the ends of both duct sections are flat, square, and free from obvious damage. Confirm that the longitudinal seams are properly closed and that the joining edges used for the S Cleats and Drive Cleats are complete and uniform. Remove any burrs or local deformation that could interfere with cleat installation.
- Inspect the cleats: Make sure the S Cleats and Drive Cleats are straight and free from obvious distortion, and that their profiles and material thicknesses match the duct joint. The S Cleat is generally sized to match the corresponding duct side, while the Drive Cleat is typically slightly longer than the corresponding side to provide enough material for folding and securing the ends after installation.
- Prepare the tools and materials: Have a rubber or wooden mallet, hand seamer or bending tool, sealant gun, and suitable duct sealant ready. If additional fastening is required, also prepare a drill, screws, or rivets. Wear appropriate PPE, including cut-resistant gloves and eye protection.
Before installation, confirm that the duct dimensions, pressure class, cleat profile and gauge, reinforcement method, and sealing method comply with the project specifications and applicable duct construction standards.
Step 2: Install the S Cleats
- Determine the installation position: S Cleats are typically installed on the two longer opposite sides of the rectangular duct.
- Align and install the S Cleat: Align the two duct sections and position the S Cleat channels over their corresponding joining edges. Slide or gently tap the cleat into place from one end until both duct edges are fully engaged.
Alternatively, the S Cleat can be installed on one duct section first, followed by inserting the corresponding edge of the second section into the remaining channel. In either method, make sure both duct edges are fully engaged and properly aligned. - Install the second S Cleat: Repeat the process on the opposite side. Once both S Cleats are fully engaged, they hold the duct edges together and maintain alignment for the subsequent Drive Cleat installation.
Step 3: Install the Drive Cleats
Drive Cleats lock the remaining two sides to complete the S & Drive mechanical connection.
- Align the duct sections:Make sure both duct ends are square and properly aligned, especially along the edges where the Drive Cleats will be installed. Use clamps for temporary positioning if needed.
- Drive the cleat into place:Drive Cleats are typically installed on the two shorter sides of the rectangular duct, such as the vertical sides of a horizontally installed duct. Position the cleat over the aligned joining edges and drive it progressively and evenly into place with a rubber or wooden mallet until it fully captures both edges.
Avoid excessive force or repeated striking in one area, as this can deform the duct edge, damage the cleat, or affect the protective coating. - Check the position:Make sure the Drive Cleat is fully seated, with sufficient length remaining at both ends for locking. Confirm that the duct sections remain square, closely fitted, and properly aligned.
Step 4: Lock the Drive Cleats
- Fold the ends: Once the Drive Cleat is fully installed, use a hand seamer, bending tool, or other suitable tool to fold the projecting ends or formed locking tabs at the duct corners.
- Secure the folded sections: Make sure the folded portions sit closely against the adjacent duct surface or joint structure. This limits movement of the Drive Cleat and improves joint stability.
- Install the opposite side: Repeat the Drive Cleat installation and locking process on the other shorter side of the duct. Once completed, the S Cleats and Drive Cleats together form a complete four-sided mechanical connection.
Step 5: Seal the Joint
After the mechanical connection is completed, appropriate sealing should be applied according to the required duct airtightness or leakage class. Areas that typically require particular attention include:
- The four corners: Especially where the S Cleats and Drive Cleats meet, as these are common potential leakage points.
- Joints between the cleats and duct: Apply duct sealant continuously or use the specified sealing material where required by the project.
- Other potential leakage points: Any locations within the specific joint configuration that may create an air leakage path should also be treated according to project requirements.
Suitable duct sealant, approved sealing tape, or other specified sealing materials may be used according to project requirements. The exact sealing area and method should be determined according to system pressure, leakage class, and applicable construction standards.
Step 6: Additional Fastening and Inspection
For certain larger ducts, higher pressure classes, or special joint configurations, project specifications may require additional mechanical fastening or duct reinforcement.
- Screws or rivets: Where required by the project specification, self-tapping screws, blind rivets, or other mechanical fasteners can be installed at specified locations to further restrict movement between the cleats and duct.
- Final inspection: Confirm that the S Cleats and Drive Cleats are correctly seated, the ends of the Drive Cleats are secured, the duct joint remains square, and the sealing is continuous and complete.
- Duct support: The S & Drive Connection itself is not a substitute for duct hangers or supports. The duct should still be independently supported according to project requirements.
The location, quantity, and spacing of any additional fasteners should be determined according to the project specifications and applicable duct construction standards.
Advantages of S & Drive Connections
1. Lower Material and Connection Costs
Compared with traditional angle steel flanges, an S & Drive Connection uses S Cleats and Drive Cleats formed from thin sheet metal and does not require a complete angle steel flange frame or large quantities of bolts and nuts.
It uses less connecting material and also reduces common angle-flange fabrication processes such as cutting, punching, welding, and assembly, helping reduce material and fabrication costs.
2. Relatively Simple Fabrication Equipment
S Cleats and Drive Cleats can be continuously produced using appropriate roll-forming equipment. Compared with complete flange fabrication and assembly processes, the required equipment and production process are relatively simple, making this approach suitable for small- and medium-scale production, supplementary fabrication, and repair or modification projects.
3. Convenient Field Installation
S Cleats and Drive Cleats are lightweight, making them easier to transport and handle on site. Installation is primarily completed through insertion, driving, and end folding, reducing the bolt alignment and tightening operations associated with traditional angle steel flange connections and helping improve installation efficiency.
4. Mature Connection Method
S & Drive Connections have been used in HVAC duct fabrication and installation for many years. Their fabrication and installation methods are well established and relatively easy to learn.
When the duct size, sheet thickness, pressure class, reinforcement, and sealing method comply with the applicable project specifications and standards, the method can provide a stable duct connection.
5. Compact Joint Structure
An S & Drive Connection does not require a large structural steel flange frame at the duct end, resulting in a more compact joint with fewer external projections. This can also be advantageous where installation space is limited.
What Are the Limitations of S & Drive Connections?
1. Not Suitable for Large, High-Pressure Ducts
S & Drive Connections are generally better suited to smaller rectangular ducts and lower-pressure systems. As duct size or system pressure increases, the joint is subjected to greater loads, while the duct walls become more susceptible to deformation and vibration.
2. Relatively Lower Joint Rigidity
S Cleats and Drive Cleats primarily connect and secure the duct edges rather than forming a rigid flange frame. As a result, they provide less structural reinforcement than TDF/TDC or angle steel flange connections, particularly as duct size and pressure increase.
3. Airtightness Is More Sensitive to Joint Quality
An S & Drive Connection contains several potential leakage points, including the four corners, S Cleat channels, Drive Cleat interfaces, and longitudinal seams near the joint.
Because the connection consists of multiple separate cleats and interfaces, its airtightness is more sensitive to fabrication tolerances, cleat fit, and sealing quality.
4. Sensitive to Fabrication and Installation Quality
Out-of-square duct ends, deformed edges, distorted S Cleats, or incompletely seated Drive Cleats can result in loose joints, misalignment, or local gaps.
Excessive hammering during installation can also deform the cleat or duct edge, affecting both the fit and overall joint quality.
5. Limited Tolerance for Dimensional Errors
S & Drive Connections require good dimensional consistency, squareness, and edge alignment. Oversized, undersized, distorted, or poorly aligned duct ends can cause the cleats to bind or make assembly difficult.
Compared with bolted flange connections, S & Drive joints also provide less adjustment for dimensional or alignment errors during assembly.
6. Less Convenient to Disassemble and Reinstall
Although Drive Cleats can generally be removed, the S Cleats remain captured between the two duct sections. Accessing or replacing an S Cleat may require unfolding the Drive Cleat ends or partially dismantling the joint.
This makes S & Drive Connections less convenient where frequent disassembly, maintenance, or duct reconfiguration is required.
S & Drive vs. TDF/TDC Flange: What Is the Difference?
S & Drive and TDF/TDC are both common transverse connection methods for rectangular metal ducts, but they differ significantly in their connection structure, rigidity, fabrication method, field installation, and typical applications.
An S & Drive Connection uses a separate connection structure, with independent S Cleats and Drive Cleats providing connection and locking.
A TDF/TDC Flange Connection uses a flange-based structure. The duct ends are formed into the appropriate flange profiles and are typically assembled using corner pieces, clips/cleats, and sealing materials.
Simply put, S & Drive uses separate cleats to connect the duct edges, while TDF/TDC uses flange profiles formed at the duct ends.
| Comparison | S & Drive Connection | TDF/TDC Flange Connection |
| Connection Structure | Separate S Cleats + Drive Cleats | Duct-end flanges + corner pieces/clips |
| Joint Rigidity | Relatively lower | Generally higher |
| Typical Application Range | More common for smaller, lower-pressure rectangular ducts | Generally suitable for larger sizes and higher structural requirements |
| Sealing Performance | More dependent on sealing at corners, cleats, and seams | Continuous flange surfaces facilitate more consistent sealing |
| Fabrication Method | Cleats are produced using suitable roll-forming equipment | Requires appropriate TDF/TDC flange-forming equipment |
| Field Installation | Cleats are slid/driven into place, ends folded, and joint sealed | Flanges are aligned, corner pieces/clips installed, and joint sealed |
| Sensitivity to Installation Quality | More sensitive to duct squareness, cleat fit, and field workmanship | Generally more standardized, although correct assembly and sealing are still required |
| Equipment Investment | Related forming equipment is relatively simple | Flange-forming and supporting equipment is generally more complex |
| Maintenance & Disassembly | Cleat removal and reinstallation are relatively inconvenient | Flanged construction is generally easier to disassemble and reconnect |
| Typical Advantages | Simple structure, lower material use, and lower cost | Higher rigidity and greater standardization; better suited to large-scale production |
For smaller, lower-pressure rectangular ducts, smaller production volumes, or applications where simpler connector fabrication is preferred, an S & Drive Connection can provide an economical and mature solution.
When duct dimensions, system pressure, joint rigidity, or airtightness requirements increase, or when a project places greater emphasis on standardized production and high-volume fabrication efficiency, a TDF/TDC Flange Connection is generally more advantageous.
For a more detailed comparison of TDC and TDF flange systems, see our guide: TDC vs. TDF Duct Connection
How to Choose an S & Drive Cleat Forming Machine?
When selecting an S & Drive Cleat Forming Machine, key considerations include the cleat type, material and sheet thickness, roller quality, production capacity, and machine stability. The appropriate configuration should be selected according to actual duct fabrication requirements.
1. Cleat Type and Profile
First, confirm that the machine can produce the required S Cleat, Drive Cleat, or other cleat profiles, and check whether the finished profile dimensions meet the actual duct connection requirements.
If multiple cleat profiles are required, also check the available forming types and how the machine supports profile changeover or adjustment.
2. Material and Sheet Thickness Range
The machine’s processing range must match the duct materials used in production. In addition to the maximum sheet thickness, consider feeding, roll-forming, and continuous operating stability throughout the commonly used thickness range.
For example, the Suntay SA-12S S Lock Forming Machine can process 0.5–1.2 mm sheet metal, covering common thin-sheet duct fabrication requirements.
3. Roller Material and Forming Quality
The forming rollers are core components of the machine. Their material, hardness, machining accuracy, and wear resistance directly affect cleat profile consistency and the machine’s long-term service life.
When selecting a machine, pay particular attention to rollers made from strong, wear-resistant materials with appropriate heat treatment. For example, the Suntay S Lock Forming Machine uses GCr15 high-strength bearing steel rollers to improve wear resistance and long-term operating stability.
The finished cleat should also be checked for good straightness, profile consistency, and surface quality.
4. Production Speed and Operating Stability
Production speed should match the actual order volume and overall duct fabrication capacity. For continuous batch production, consider not only forming speed but also the machine’s feeding stability, forming consistency, and mechanical reliability during extended operation.
A higher nominal speed alone does not necessarily result in higher actual production efficiency.
5. Motor Power and Drive System
Motor power should be appropriate for the machine’s sheet thickness range, forming profile, and production capacity. Insufficient power may affect stable forming of thicker sheet metal, while simply choosing a larger motor is not necessarily beneficial.
For example, the Suntay SA-12S uses a 2.2 kW motor, matched to its 0.5–1.2 mm processing range.
The stability of the drive system, machine frame, and shafts should also be considered to ensure that the rollers maintain proper positioning and forming accuracy during continuous operation.
About Suntay
Suntay specializes in HVAC duct fabrication machinery and solutions, providing equipment for different stages of rectangular and round duct production.
For S & Drive duct connection fabrication, Suntay offers lock forming machines with different forming profiles and configurations, helping duct manufacturers efficiently and consistently produce the required seams and connection profiles. Suntay also provides auto duct lines, TDF/TDC flange forming equipment, folding machines, Pittsburgh lock forming machines, duct grooving machines, and other HVAC duct fabrication equipment.
Contact Suntay to learn more about our HVAC duct fabrication equipment and find the right solution for your production requirements.